Portable High-Frequency (CP) X-ray Generator: DIYE-160GD/225GD/300GD/300GP Model


+
  • 最新高频.png
  • 微信图片_20251117154127_634_16(1).png
  • c22-5.jpg
  • 控制箱.png

Product Details


Technical Parameters

Model DIYE-160B DIYE-225GD DIYE-300GD DIYE-300GP
Photo 160GD DIYE-225GD DIYE-300GD DIYE-300GP
X-ray tube Metal-ceramic tube Metal-ceramic tube Metal-ceramic tube(Imported) Metal-ceramic tube
Power supply mode Constant voltage Constant voltage Constant voltage Constant voltage
Tube voltage adjustment range 40-160KV 100-225kV 50-300kV 50-300kV
Voltage adjustment step 1kV/step 1kV/step 1kV/step 1kV/step
X-ray Tube Maximum Power 500W 900W 900W 600W
Tube current 0.1-0.5mA 0.5-3mA 0.5-3mA 0.5-2mA
Current adjustment step 0.1mA/step 0.1mA/step 0.1mA/step 0.1mA/step
Maximum Exposure Time Setting 30min 30min 30min 25min
Continuous Exposure Time (at 35°C) 30min 30min 30min /
Exposure Data Records 100sets 100sets 100sets /
High Voltage Delay Adjustment Range 59minutes59seconds 59minutes59seconds 59minutes59seconds 0-99s
Operating frequency 100kHz 100kHz 100kHz 100kHz
Focal spot size 0.8*0.8mm Acc.EN12543 d=2.5mm
Acc.EN12543 d=1.0mm((Optional)
Acc.EN12543 d=3.0mm Acc.EN12543 0.5×5.5mm
Penetration Thickness 32mm(A3 steel, focal length 600mm) 45mm(A3 steel, focal length 600mm) 65mm(A3 steel, focal length 600mm) 55mm(A3 steel, focal length 700mm, D7 film, negative density ≥ 2.0, 25 minutes)
Duty Cycle / / / 100% (at ambient temperature 20°C and maximum power conditions)
Radiation Angle 45° 45° 45° 38°x 360°
Tube head size Φ124mm*513mm Φ295mm*702mm(including end rings)
Φ215mm*597mm(excluding end rings)
Φ295mm*750mm(including end rings)
Φ215mm*645mm(excluding end rings)
high:791*320mm(including end rings)
Tube head weight Total weight including (battery)10.3kg 23kg 26kg 30.5kg
Connecting cables 20M 25M 20M 25M
Power cable 10M 10M 10M 10M
Controller size 350mm*330mm*170mm 465mm*154mm*323mm 350mm*330mm*170mm 433mm*153mm*369mm
Controller weight Total weight including (battery)10.3kg 10kg 10kg 11.3kg
Input power 200-250VAC,47-400Hz 200-250VAC,47-400Hz 200-250VAC,47-400Hz 200-250VAC,47-400Hz
Anode cooling method / / / Forced air cooling
Operating Temperature Range -20℃~+50℃ -20℃~+50℃ -20℃~+50℃ -20℃~+50℃
Configuration List X-ray generator (1 unit)
controller (1 unit)
high-voltage connecting cable (1 unit)
power cable (1 unit)
alarm light (1 unit)
ground wire (1 unit)
2A/20A fuses (5 units each)
transport case (1 unit)
remote control via mobile phone (optional)
GPS positioning (optional)
X-ray generator (1 unit)
controller (1 unit)
high-voltage connecting cable (1 unit)
power cable (1 unit)
alarm light (1 unit)
ground wire (1 unit)
2A/20A fuses (5 units each)
transport case (1 unit)
remote control via mobile phone (optional)
GPS positioning (optional)
X-ray generator (1 unit)
controller (1 unit)
high-voltage connecting cable (1 unit)
power cable (1 unit)
alarm light (1 unit)
ground wire (1 unit)
2A/20A fuses (5 units each)
transport case (1 unit)
remote control via mobile phone (optional)
GPS positioning (optional)
X-ray generator (1 unit)
controller (1 unit)
high-voltage connecting cable (1 unit)
power cable (1 unit)
alarm light (1 unit)
ground wire (1 unit)
fuses (5 units each, 20A/2A/10A)
cable bag (1 unit)
aluminum alloy packaging box (1 unit)

Video Introduction
 

 

Application

     

google-site-verification: google8663a909eba9ba89.html